Boiler Water

BCI-S100C powder

BOILER CORROSION INHIBITOR/OXYGEN SCAVENGER -ALKALINE SULPHITE BASE

BCI-S100-C is a specialized, catalyzed and concentrated boiler oxygen scavenger and corrosion inhibitor for low and medium-high pressure steam generating systems.

Request More Info

    Appearance:Pale Pink Fine Powder
    Total Solids:95-98%

    Appearance 20% BCI-S100-C + 80% demin/soft water m/m
    Appearance:Deep Crimson Liquid
    Total Activity:20%
    pH neat soln. at 25°C:10.0 -12.0
    Specific Gravity at 25°C:1.18 – 1.24

    The dissolved 20% BCI-S100-C is nominally controlled at between 15-30mg/l in the boiler as the sodium sulphite compound in the boiler circuit water. These dosages should be
    altered dependent upon dissolved oxygen content in the feed water.

    mg/l dosage to boiler feed water = 5 x [ (Oxygen in Feed Water x 8) + (Residual
    Required/Effective Cycles of Concentration.)]

    There is a specific test method for the determination of the residual sodium sulphite. This is a titrimetric method and is immediately available.

    The BCI-S100-C is also available as a ready to use liquid BCI-L20-C, the dosages and residuals can be controlled exactly as described above.